All the prefabricated modules of the houses are produced in a short time at the high-tech manufacturing plant.

An elaborate layout and design of this type of houses will satisfy the demands of the most faultfinding homeowner

All homes possess high quality finishing, wiring layout, lighting and plumbing fixtures installed Our experts, together with local helpers, will assemble the house at the site in few days. You will only have to connect communications and enjoy your comfortable accommodation.

Advantages

The strength properties and other qualities of the houses have allowed to put them into the class of long-lasting buildings. All the prefabricated modules of the houses are produced in a short time at the high-tech manufacturing plant. It's new technology, they began to produce the profile for frame construction, called "thermoprofile ", with notchings, which extended "cold bridges" and reduced heat loss by about 90%. The problem of high thermal conductivity was solved but the advantages of constructions made of light thin-walled steel structures remained:

  • Short construction terms. Construction of private 2-storey house of 150 m2 "turnkey" takes about 10 days;
  • Free layout due to the possibility to arrange the spans without intermediate supports of up to 9-12 m;
  • Production of the main parts at the factory, which ensures high accuracy;
  • Low weight allowing a small team of workers to set a house on a concrete pad;
  • Low cost in comparison with other technologies.

Prefabricated Home Specifications

1.      GENERAL SYSTEM DESCRIPTION

Manufacturing Technology

Carrier systems used in steel properties;

DIN EN 10326 standard in S320GD + Z + AZ Erdemir quality no: 1332, S350GD+Z+AZ Erdemir quality no:1335 and/or Erdemir quality no: 1322 d.

Static Accounts

Construction of the suitability of the intended use and building 's been there by region necessary seismic and static calculations, project and set the standart load According to the values specified in 3rd item and Turkish standards and / or According to an international standard; Sap2000 are made with programs.

Thermal (Climate) Calculation

Outer Wall and Roof, taking into account the building's climate conditions of the region This can make;

Snow load

80 kg / m² (varies by region.)

 

Wind Speed

90 kg / m 2 (varies by region.)

 

Earthquake Conditions

1 Rank (varies by region.)

   

Climate Conditions

3. Regional climate conditions

 

TS 825 is also recommended to conform to and elaborating Insulation Values

In this account moving loads of 200 kg / m2, and still loads of 400 kg / m2 has been taken as a basis.

       

2.      WALL PANELS

walls

TS 825 Insulation Values Recommended according SUPPLIED HEAT INSULATION VALUE

 

For 1.climate Zone

0.80 W / m2K ......... 0.442 W / m2K (Compliant)

For 2.climate Zone

0.60 W / m2K ......... 0.442 W / m2K (Compliant)

For 3.climate Zone

0.50 W / m2K ......... 0.442 W / m2K (Compliant)

For 4.climate Zone

0.40 W / m2K ......... 0.398 W / m2K (Compliant)

The wall panels are made of double-sided carbide fiber-cement plates with dimensions 8X1250X2500 mm.

Wall Thickness

 

Exterior 100 mm

Interior 60 -100 mm

Wall Cladding

 

8 mm thick cemented board (CE certificated)

Heat and Sound Insulation Materials

84-44 mm thick polystyrene foam (16 kg / m3)

Fire Resistance

 

DIN 4102 that "The hard flammable materials", "B1" is class

Carrier Panel Construction

 

Galvanized thermoprofile H, which excludes the occurrence of "cold bridges" at the junction, a thickness of 1.2 mm corresponds to static calculations.

 

3.      CARRIER CONSTRUCTIONS

carrier

Roof trusses, the wall connection elements - H s beams and columns, special twisted stainless made from galvanized steel

Because no corrosion occurs as a result of radial sweating.

used in building the roof truss ranges vary depending on the ceiling system. Standard Omega suspended from the ceiling 125 cm apart.reverse satin plaster ceiling 187 cm apart, the ceiling plate 60x60 mineral 250cm apart shear is applied.

Demountable structures that mounting bolts are used repeatedly.

4.      MIDDLEWARE CONSTRUCTION (FOR DUPLEX BUILDINGS)

middleware

Middleware galvanized steel supporting structure is made in a special way, it was raised from shee metal bent CA . Middleware on 16 mm carrier fiber (cement chipboard) covered as sound insulation above a suspended ceiling plasterboard is 80 mm thick glass wool series.

The carrying capacity of 200 kg / m²

5.      STAIRS (FOR DUPLEX HOUSES)

stairs

16mm in thickness on the steel skeleton obtained from box profile fiber cement board covered with material.Stair railings are made of box profile , Frame of stairs painted with double coating and double layer paint.

6.      ROOF DETAILS

roof

TS 825 Insulation Values Recommended according SUPPLIED HEAT INSULATION VALUE

For 1.climate Zone

0.50 W / m2K ......... 0.440 W / m2K (Compliant)

For 2.climate Zone

0.40 W / m2K ......... 0.361 W / m2K (Compliant)

For 3.climate Zone

0.30 W / m2K ......... 0.234 W / m2K (Compliant)

For 4.climate Zone

0.25 W / m2K ......... 0.234 W / m2K (Compliant)

Roof Carrier System

It is composed of galvanized sheet specially designed profile Box profiles are used

Roofing

0.50 mm thick galvanized trapezoidal sheet roofing painted as applied

Insulation Material

80 mm thick glass wool (14 kg / m3) (for 1.İkl Region)

Insulation Material

100 mm thick glass wool (14 kg / m3) (for 2.İkl Region)

Insulation Material

160 mm thick glass wool (14 kg / m3) (for 3rd-4th Climate Region)

Ceiling Construction

Omega are designed specifically PROFILES

rain Gutters

Square section of the creek and landing s PVC

Fringe Coating

20 cm wide galvanized steel has been specially shaped d

7.      CEILING

celling

For ceiling coating, plaster boards in thickness of 12.5 mm

Drywall connection elements are made of powder coated aluminum

8.      TRANSOM WINDOWS AND WINDOWS

windows

Species

:

Our window of 62 series unleaded PVC joinery

Windowpane

:

4 + 12 + 4 double glazing

Transom Window

:

4 mm thick frosted glass

9.      OUTDOORS

outdoors

Door Dimensions

:

90 * 200 steel doors (Prefabricated houses use steel doors with outer doors)

Door Case

:

Steel

   

Surface Coating

:

Wooden walnut

 

Lock System

:

Ball cylinder lock and safety lock (castle brand)

Door handle

:

Aluminum, painted yellow

Hinge

:

Special hinged

 

10. INTERIOR DOORS

doors

Door Case

:

30 mm thick wooden case is applied

Surface Coating

:

Olympos patterned American panel door

Filling Material

:

Kraft paper

Lock System

:

Nail lock

Door handle

:

Aluminum, Gray painted

Hinge

:

Body color hinged

11. ELECTRICAL INSTALLATION

electrcal

Electrical installation uses with TSE Certified, and with first quality materials.

The system is laid under the ceiling through the wall.

General

:

Electrical materials uses with TSE Certificated and with first quality m

Keys and sockets

:

TSE Certificated and with first quality materials.

Armature

:

TSE certified. Lighting in the living areas is provided with double luminaries

Insurances

:

TSE certified SİEMENS brand automat

Cable Installation 250V

:

TSE certified,  3x2,5 NYM and NYA cables are used, switches And 2x0.75 TTR cable for lighting fixtures.

The electric meter, grounding and external connection  will be made by the Customer.

Electric stove, air conditioning, electric radiators, boilers should be specified in the project.

Electric Panels will be made by the Customer.

Each power device will be supplied with a separate fuse line.

12. WATER INSTALLATIONS

water

The clean water installation is furnished inside the wall, using TSE certified materials.

Plumbing application is provided by the manufacturer on turnkey projects.

Clean water and sewage system 1 meter is taken out of the building.

Dirty water and clean water main line external connections belong to the customer.

General

:

Quality materials are used according to TSE standards.

Vitrified Materials

:

Vitrified materials uses with TSE Certificated and with first quality materials

Armatures

:

Armatures uses with TSE Certificated and with first quality materials.

Clean Water Pipes

:

PPR-C pipe and pipe connections uses with international certificates and first quality.

Waste Water Pipes

:

PVC pipes and fittings uses with international certificates and first quality.

Washbasin

:

45 * 55 cm sized washbasin with wall mounting foot.

Shower

:

90 cm x 90 cm glass shower cabin is used.

Closet

:

TSE certified, stone recycled ceramic toilet bowl is used.

Alaturka Stone

:

With TSE certificate, ceramic tile with built-in drawer

Urinal

:

TSE certified, wall mounted ceramic urinal and urinal compartment

Kitchen sink

:

It is 100 cm x 50 cm in dimensions with wood chipboard cabinet and metal counter top.

13. PAINT

paint

Exterior

:

2 times Acrylic exterior paint (colors will be selected by customer)

Interior Wall

:

2 times Plastic paint (colors will be selected by customer)

Ceiling

:

2 times Plastic paint (colors will be selected by customer)

Insulation filling is applied to the panel connection, ceiling and roof details

14. GROUND CONCRETE

concrete

Ground Concrete belongs to the customer. However, it can also be applied by the vendor in turnkey projects.

All information and drawings for the preparation of the ground concrete are given to the customer by us.

15. WARRANTY

Warranty coverage is given as 2 years for assembly and material.

16. GENERAL PRODUCTION INSTALLATION INFORMATION

Ecotech-BG buildings built on the ground concrete, when requested, It can be reinstalled elsewhere.

The walls that make up the structure are not carriers, so there is no deformation on the walls.

Galvanized steel H, columns and beams with all the static calculations of the load are carried.

The weights of the parts that make up the prefabricated are light enough that two people can carry it.

Loading, unloading can be done with human power

Ecotech-BG has right to make modifications on Technical Specification.